Description
5 -Channel Class AB (Front + Side) & Class D (Sub Out) Amplifier (1 & 2 X 76w @ 4-Ohms, 3 & 4 X 134w @ 4-Ohms, 5 X 560w @ 4-Ohms, 5 X 882w @ 2-Ohms)
Features:
• 5 channel amplifier
• Available in Black/Silver finishing
Specifications:
• DC-DC converter typology / Conversion frequency: Unregulated Push-Pull / 50 Khz (managed by microcontroller)
• Supply voltage range operation: 9 V ÷ 16 V (Absolute maximum) / 11 V ÷ 14.4 V (Recommended)
• Under / Over Voltage Safety Thresholds: 8 V (1 sec. 6V sustaining for Start & Stop) / 16 V
• Mute delay time: 4 secs.
• Secondary voltages (VDD#12 /VDD#34 /VDD#5 / DRIVE / SERV): ±33.1 V / ±45.3 V / ±84.7 V / ±14 V / ±15 V
• Max output offset voltage (each channel): ±15 mV
• Standby current: < 1 mA (typical)
• Quiescent consumption @ 12V6 / 14V4: 1.90 A / 2.15 A (no idle current regutation)
• Idle current regulation (no signal): 0.05 A (each trimmer)
• Quiescent consumption @ 14V4: 2.25 A (with idle current setted)
• Thermal protection consumption: 140 mA
• Thermal cutoff Threshold: 90°C (CH5 cutoff) / 100°C (Overall cutoff) / 70°C (resume to normal operation)
• ProSPEED® Fan Controller Threshold: 50°C (start) / 45°C (stop) / 70°C (max speed)
• Damping factor @ 100 Hz - 10 Watt ref (Right / Left): 319/397 [CH1/2] - 318/487 [CH3/4] - 153 [CH5]
• Damping factor @ 1 KHz - 10 Watt ref (Right / Left): 291/375 [CH1/2] - 304/453 [CH3/4] - 101 [CH5]
• Damping factor @ 10 KHz - 10 Watt ref (Right / Left): 178/199 [CH1/2] - 183/219 [CH3/4] - n.a. [CH5]
• Load drive limitations (*): 2 Ohm / 4 Ohm (Stereo / Bridged)
• Suggested fuse: 150 A (Internal)
Features:
• 5 channel amplifier
• Available in Black/Silver finishing
Specifications:
• DC-DC converter typology / Conversion frequency: Unregulated Push-Pull / 50 Khz (managed by microcontroller)
• Supply voltage range operation: 9 V ÷ 16 V (Absolute maximum) / 11 V ÷ 14.4 V (Recommended)
• Under / Over Voltage Safety Thresholds: 8 V (1 sec. 6V sustaining for Start & Stop) / 16 V
• Mute delay time: 4 secs.
• Secondary voltages (VDD#12 /VDD#34 /VDD#5 / DRIVE / SERV): ±33.1 V / ±45.3 V / ±84.7 V / ±14 V / ±15 V
• Max output offset voltage (each channel): ±15 mV
• Standby current: < 1 mA (typical)
• Quiescent consumption @ 12V6 / 14V4: 1.90 A / 2.15 A (no idle current regutation)
• Idle current regulation (no signal): 0.05 A (each trimmer)
• Quiescent consumption @ 14V4: 2.25 A (with idle current setted)
• Thermal protection consumption: 140 mA
• Thermal cutoff Threshold: 90°C (CH5 cutoff) / 100°C (Overall cutoff) / 70°C (resume to normal operation)
• ProSPEED® Fan Controller Threshold: 50°C (start) / 45°C (stop) / 70°C (max speed)
• Damping factor @ 100 Hz - 10 Watt ref (Right / Left): 319/397 [CH1/2] - 318/487 [CH3/4] - 153 [CH5]
• Damping factor @ 1 KHz - 10 Watt ref (Right / Left): 291/375 [CH1/2] - 304/453 [CH3/4] - 101 [CH5]
• Damping factor @ 10 KHz - 10 Watt ref (Right / Left): 178/199 [CH1/2] - 183/219 [CH3/4] - n.a. [CH5]
• Load drive limitations (*): 2 Ohm / 4 Ohm (Stereo / Bridged)
• Suggested fuse: 150 A (Internal)